# Keba Binding
This binding integrates the Keba KeContact EV Charging Stations (opens new window).
# Supported Things
The Keba KeContact P20 and P30 stations which are providing the UDP interface (P20 LSA+ socket, P30 c-series and x-series) are supported by this binding, the thing type id is kecontact
.
# Thing Configuration
The Keba KeContact P20/30 requires the IP address as the configuration parameter ipAddress
.
Optionally, a refresh interval (in seconds) can be defined as parameter refreshInterval
that defines the polling of values from the charging station.
# Channels
All devices support the following channels:
Channel ID | Item Type | Read-only | Description |
---|---|---|---|
state | Number | yes | current operational state of the wallbox |
enabled | Switch | no | activation state of the wallbox |
maxpresetcurrent | Number:ElectricCurrent | no | maximum current the charging station should deliver to the EV in A |
maxpresetcurrentrange | Number:Dimensionless | no | maximum current the charging station should deliver to the EV in % |
power | Number:Power | yes | active power delivered by the charging station |
wallbox | Switch | yes | plug state of wallbox |
vehicle | Switch | yes | plug state of vehicle |
locked | Switch | yes | lock state of plug at vehicle |
I1/2/3 | Number:ElectricCurrent | yes | current for the given phase |
U1/2/3 | Number:ElectricPotential | yes | voltage for the given phase |
output | Switch | no | state of the X1 relais |
input | Switch | yes | state of the X2 contact |
display | String | no | display text on wallbox |
error1 | String | yes | error code state 1, if in error (see the KeContact FAQ) |
error2 | String | yes | error code state 2, if in error (see the KeContact FAQ) |
maxsystemcurrent | Number:ElectricCurrent | yes | maximum current the wallbox can deliver |
failsafecurrent | Number:ElectricCurrent | yes | maximum current the wallbox can deliver, if network is lost |
uptime | Number:Time | yes | system uptime since the last reset of the wallbox |
sessionconsumption | Number:Energy | yes | energy delivered in current session |
totalconsumption | Number:Energy | yes | total energy delivered since the last reset of the wallbox |
authreq | Switch | yes | authentication required |
authon | Switch | yes | authentication enabled |
sessionrfidtag | String | yes | RFID tag used for the last charging session |
sessionrfidclass | String | yes | RFID tag class used for the last charging session |
sessionid | Number | yes | session ID of the last charging session |
setenergylimit | Number:Energy | no | set an energy limit for an already running or the next charging session |
authenticate | String | no | authenticate and start a session using RFID tag+RFID class |
maxpilotcurrent | Number:ElectricCurrent | yes | current offered to the vehicle via control pilot signalization |
maxpilotcurrentdutycyle | Number:Dimensionless | yes | duty cycle of the control pilot signal |
# Example
demo.Things:
Thing keba:kecontact:1 [ipAddress="192.168.0.64", refreshInterval=30]
demo.items:
Number:Dimensionless KebaCurrentRange "Maximum supply current [%.1f %%]" {channel="keba:kecontact:1:maxpresetcurrentrange"}
Number:ElectricCurrent KebaCurrent "Maximum supply current [%.3f A]" {channel="keba:kecontact:1:maxpresetcurrent"}
Number:ElectricCurrent KebaSystemCurrent "Maximum system supply current [%.3f A]" {channel="keba:kecontact:1:maxsystemcurrent"}
Number:ElectricCurrent KebaFailSafeCurrent "Failsafe supply current [%.3f A]" {channel="keba:kecontact:1:failsafecurrent"}
String KebaState "Operating State [%s]" {channel="keba:kecontact:1:state"}
Switch KebaSwitch "Enabled" {channel="keba:kecontact:1:enabled"}
Switch KebaWallboxPlugged "Plugged into wallbox" {channel="keba:kecontact:1:wallbox"}
Switch KebaVehiclePlugged "Plugged into vehicle" {channel="keba:kecontact:1:vehicle"}
Switch KebaPlugLocked "Plug locked" {channel="keba:kecontact:1:locked"}
DateTime KebaUptime "Uptime [%s s]" {channel="keba:kecontact:1:uptime"}
Number:ElectricCurrent KebaI1 {channel="keba:kecontact:1:I1"}
Number:ElectricCurrent KebaI2 {channel="keba:kecontact:1:I2"}
Number:ElectricCurrent KebaI3 {channel="keba:kecontact:1:I3"}
Number:ElectricPotential KebaU1 {channel="keba:kecontact:1:U1"}
Number:ElectricPotential KebaU2 {channel="keba:kecontact:1:U2"}
Number:ElectricPotential KebaU3 {channel="keba:kecontact:1:U3"}
Number:Power KebaPower "Energy during current session [%.1f Wh]" {channel="keba:kecontact:1:power"}
Number:Energy KebaSessionEnergy {channel="keba:kecontact:1:sessionconsumption"}
Number:Energy KebaTotalEnergy "Energy during all sessions [%.1f Wh]" {channel="keba:kecontact:1:totalconsumption"}
Switch KebaInputSwitch {channel="keba:kecontact:1:input"}
Switch KebaOutputSwitch {channel="keba:kecontact:1:output"}
Number:Energy KebaSetEnergyLimit "Set charge energy limit [%.1f Wh]" {channel="keba:kecontact:1:setenergylimit"}
demo.sitemap:
sitemap demo label="Main Menu"
{
Text label="Charging Station" {
Text item=KebaState
Text item=KebaUptime
Switch item=KebaSwitch
Switch item=KebaWallboxPlugged
Switch item=KebaVehiclePlugged
Switch item=KebaPlugLocked
Slider item=KebaCurrentRange
Text item=KebaCurrent
Text item=KebaSystemCurrent
Text item=KebaFailSafeCurrent
Text item=KebaSessionEnergy
Text item=KebaTotalEnergy
Switch item=KebaSetEnergyLimit
}
}
# Troubleshooting
# Enable Verbose Logging
Enable DEBUG
or TRACE
(even more verbose) logging for the logger named:
org.openhab.binding.keba
If everything is working fine, you see the cyclic reception of report 1
, 2
& 3
from the station. The frequency is according to the refreshInterval
configuration.
# UDP Ports used
Send port = UDP 7090
The Keba station is the server
Receive port = UDP 7090
This binding is providing the server
UDP port 7090 needs to be available/free on the openHAB server.
In order to enable the UDP port 7090 on the Keba station with full functionality, DIP switch 1.3
must be ON
.
With DIP switch 1.3 OFF
only ident-data can be read (i
and report 1
) but not the other reports as well as the commands needed for the write access.
After setting the DIP switch, you need to power OFF
and ON
the station. SW-reset via WebGUI seems not to be sufficient in order to apply the new configuration.
The right configuration can be validated as follows:
- WebGUI DSW Settings:
DIP 1.3 | ON | UDP interface (SmartHome)
- UDP response of
report 1
:DIP-Sw1
0x20
Bit is set (enable at leastDEBUG
log-level for the binding)
# Supported stations
- KeContact P20 charging station with network connection (LSA+ socket)
- Product code:
KC-P20-xxxxxx2x-xxx
orKC-P20-xxxxxx3x-xxx
- Firmware version: 2.5 or higher
- Product code:
- KeContact P30 charging station (c- or x-series) or BMW wallbox
- Firmware version 3.05 or higher
← Kaleidescape KM200 →